Modular Camp Solutions for Project Sites

Shown configuration ยท final layout and fit-out by quotation.

Building System: Flat Pack Container House Building Function: Hospitality

Flat Pack Guest Room Module

A flat pack guest-room module for resort, lodge and project hospitality layouts where room consistency and finish coordination matter.

Shown external or deployed size

6055 x 2990 x 2896 mm

Main structural assembly reference

4 workers / 2 hours / house

Catalog loading reference

6-8 units / 40HQ

Structural frame reference

2.3 mm Q235B steel frame

Installation Advantage ยท Factory-prepared frames and enclosure components reduce on-site assembly steps. Review the timed scope.

Patent Documentation Available ยท Confirm applicability for the selected configuration.

Catalog references shown. Final scope follows the quotation and approved specification.

Product Decision Snapshot

What it is

A flat pack guest-room module for resort, lodge and project hospitality layouts where room consistency and finish coordination matter.

Who it is for

Hospitality developers, contractors, resort operators and project accommodation planners.

Shown configuration

The page presents a guest-room shell and finish direction. Bathroom type, faรงade, furniture, MEP, corridor and public areas require a project package.

Main trade-off

Lower 40HQ loading density than detachable or folding systems, with more site assembly planning.

Best Fit

  • Repeated guest rooms
  • Resort support accommodation
  • Projects with a coordinated faรงade and interior brief

Not the Best Fit

  • A complete hotel without public-area design
  • Projects requiring unlimited faรงade geometry
  • Orders without an approved room data sheet

Shown Configuration and Layout Logic

Displayed unitThe page presents a guest-room shell and finish direction. Bathroom type, faรงade, furniture, MEP, corridor and public areas require a project package.
Primary useGuest rooms, staff rooms and repeatable accommodation wings.
Layout and occupancyRoom size does not define bed type, bathroom module or occupancy. Clearances, accessibility, housekeeping, luggage storage and local hospitality codes shape the final layout.
System behaviorFactory-prepared roof and floor frames, corner posts and enclosure components are packed for site assembly into repeatable room modules. The system favors project blocks and planned combinations over the highest transport density.
Final authorityQuotation, approved drawings and approved specification

Verified Specifications

Company catalog values below apply to the stated system configuration. Where the catalog records more than one dimension or build-up, the quotation must identify the selected model and must not combine conflicting values.

External / deployed size6055 x 2990 x 2896 mm
Interior size5845 x 2780 x 2500 mm
Closed / folded referenceNot applicable
Frame2.3 mm Q235B steel frame
Walls50 mm rock wool sandwich panel
Roof / ceiling50 mm glass wool insulation in the catalog configuration
FloorMGO board or cement fiber board with finish selected by quotation
Loading6-8 units / 40HQ
Installation / deployment4 workers / 2 hours / house
Wind referenceCatalog reference: wind resistance Level 11
Seismic referenceCatalog reference: anti-seismic Grade 8

Configuration Options

Configuration options

  • Single, twin or staff-room layout
  • Private bathroom by quotation
  • Faรงade and glazing package
  • Interior finish and furniture
  • Corridor, stair and services interfaces

Scope and Responsibility Matrix

Factory SupplyOptional / By QuotationBy Client / Site Contractor
Structural shell and selected enclosureBathroom, furniture and appliancesFoundation, corridors and access
Quoted interior/MEP rough-insFaรงade and finish packageExternal utilities and public areas
Packing for approved room data sheetHVAC and controlsFinal commissioning and hospitality approval

The quotation and approved specification have final authority. Any item not listed as factory supply remains optional or by others.

Installation and Deployment Advantage

Catalog reference: 4 workers / 2 hours / house. The company catalog records 4 workers plus 2 hours for one house. It does not define every included task, so the quotation must state whether wall panels, doors, windows, sealing and lifting are inside the timed scope.

1. Site readinessFoundation or level base, drainage, access and work area complete; weather within the approved installation plan
2. Tools and handlingQuoted hand tools, fasteners, torque/sealant controls and safe lifting or handling equipment confirmed before unloading
3. Timed activityMain structural assembly reference: 4 workers / 2 hours / house
4. Enclosure completionPanels, doors, windows and seals only as identified in the timed scope
5. Interior fit-outFurniture and specialist equipment follow the quotation
6. Utility connectionExternal networks and final connections by the assigned site party
7. Testing and handoverInspection, commissioning and local approval after structural deployment

Structural Innovation and Evidence

Patent-documented structural design

Patent titleContainer Top Panel Lifting Device
Patent numberZL 2025 2 0606066.9
JurisdictionChina
Related structural featureA lifting device for handling a container top panel during assembly.
Procurement relevanceThe documented lifting concept supports a more controlled roof-panel handling step when the approved installation plan uses the applicable top-panel arrangement.
Status limitationUtility model patent certificate records grant publication on 17 February 2026; current legal status not independently verified.

Factory preparation and QC evidence. The company catalog describes automated production and checks including watertightness, penetration, roof load, stacking and side-push testing. The approved inspection and test plan for the order defines the actual hold points, records and acceptance criteria.

Patent documentation is available for review. Current legal status and product-level applicability should be confirmed for the relevant market and configuration.

Applications

Guest rooms, staff rooms and repeatable accommodation wings.

Product-Specific FAQ

The page presents a guest-room shell and finish direction. Bathroom type, faรงade, furniture, MEP, corridor and public areas require a project package. The quotation and approved specification are the final scope documents.

Room size does not define bed type, bathroom module or occupancy. Clearances, accessibility, housekeeping, luggage storage and local hospitality codes shape the final layout.

The company catalog records 4 workers plus 2 hours for one house. It does not define every included task, so the quotation must state whether wall panels, doors, windows, sealing and lifting are inside the timed scope.

The client or site contractor normally prepares the foundation, access, unloading plan and external networks unless the quotation assigns a different scope. Review the Camp Installation Responsibilities page before order.

Configuration can be reviewed against quantity, destination, climate, layout and use. A change is not included until it appears in the quotation and approved specification.

Provide intended use, quantity, destination, occupancy or floor area, project duration, site and climate conditions, preferred layout, fit-out, utilities, delivery date and available drawings.

Relocation depends on the structural system, approved handling method and the condition of frames, panels, fasteners, hinges and seals after use. Reinspection is required before reuse.

Request a Configuration Quote

Share your destination, estimated quantity and basic project requirements. KUBO will review the appropriate configuration, supply scope and next technical inputs.

KUBO Product Project Quote

Confirm the Right Configuration Before Pricing

Use, quantity, destination, layout, occupancy, site conditions and delivery schedule determine the final product configuration and supply boundary.

Scroll to Top

Get A Free Quote Now !

Contact Form
If you have any questions, please do not hesitate to contact us.
KUBO prefab container house factory overview with modular building production capacity