This confirmed KUBO project case presents one three-storey modular accommodation building configured for dormitory or staff accommodation. The plans organize 40 rooms across three floors within an approximate building footprint of 24,000 x 13,900 mm. Repeated room bays, a central corridor, mixed sanitary arrangements, external stair components and a four-slope pitched roof are brought together through a coordinated modular drawing package.
The project illustrates how we can develop a multi-storey accommodation block from repeatable steel-framed modules while adapting the internal arrangement to different floor functions. The first floor contains 16 visible en-suite rooms, whereas the upper floors combine accommodation rooms with shared washroom zones. This mixed configuration allows sanitary facilities to be distributed differently within the same overall building form rather than forcing every floor to use an identical room layout.
Project Configuration at a Glance
| Technical item | Configuration shown in the drawings |
|---|---|
| Building use | Dormitory or staff accommodation |
| Building scale | One three-storey modular accommodation building |
| Approximate footprint | 24,000 x 13,900 mm |
| Rooms shown | 40 rooms across three floor layouts |
| Typical room module | 3,000 x 5,950 mm |
| Internal circulation | 2,000 mm central corridor |
| Room-bay arrangement | Eight room bays per side per floor, with corridor and washroom modules |
| Structural system | Joined steel modular frames with bolted steel-plate connectors |
| Roof form | Four-slope pitched roof with roof and drainage installation details |
| Building services | Lighting, socket and sanitary-installation layouts |
The room count is taken directly from the three floor layouts. Bed numbers and final occupancy are not stated, so the project should be read as a 40-room accommodation configuration rather than as a defined resident-capacity figure. In practical project development, the number of residents assigned to each room would need to be confirmed separately against the intended furniture arrangement and accommodation policy.

A Central-Corridor Plan for a Repeated Room Layout
The building uses a 2,000 mm central corridor with accommodation rooms arranged on both sides. Eight room bays are positioned along each side of each floor, accompanied by the corridor and the washroom-related modules required by the relevant level. The approximate 24,000 mm building length corresponds with the repeated 3,000 mm room-bay rhythm shown in the plans.
This configuration organizes the floor plate around one clear internal circulation line. Rather than separating rooms into several disconnected groups, the central corridor connects the accommodation bays and provides a consistent approach to room entrances. It also creates a legible basis for coordinating room partitions, doors, lighting points, socket locations and sanitary zones within the overall modular grid.
The arrangement is especially relevant where a buyer is considering a dedicated accommodation block as part of a broader camp-style workforce housing solution. The building can be studied as one accommodation component within a larger site plan, while kitchens, dining facilities, offices, recreation spaces or other support buildings remain separate project decisions.
Different Sanitary Strategies Across the Three Floors
En-suite rooms on the first floor
The first-floor plan shows 16 en-suite rooms positioned around the central corridor. Each room therefore incorporates its own sanitary area within the room arrangement. The drawing package includes sanitary-installation details for these en-suite spaces, allowing the room layout and its internal service points to be considered together.
Using en-suite rooms on this level keeps the sanitary functions associated with individual rooms. From a configuration perspective, this is a straightforward way to provide a more self-contained room type within the building. It also establishes a distinct first-floor accommodation format without changing the overall central-corridor organization or the repeated room-bay width.
Shared washroom zones on the upper floors
The upper-floor layouts retain accommodation rooms and the central corridor but introduce shared washroom zones. This approach consolidates a portion of the sanitary functions into designated public or shared areas instead of placing a complete en-suite facility inside every room.
The mixed sanitary strategy demonstrates that a multi-storey dormitory does not need to repeat one room specification on every level. En-suite and shared-facility arrangements can be allocated by floor according to the intended room mix. The drawings do not state how residents would be assigned, but the configuration gives a buyer a useful basis for discussing which room categories and sanitary arrangements belong on each storey.
For buyers comparing this project with a more standardized accommodation product, the detachable dormitory block unit provides additional context for how repeated room units can support larger workforce-accommodation layouts.

Typical Room Modules and Joined Steel Frames
A typical room module is shown as 3,000 x 5,950 mm. Repeating this dimensional basis helps organize the accommodation bays, while corridor and washroom modules complete the wider floor plate. The project therefore uses modular repetition without treating the entire building as a series of isolated single-room structures.
The structural arrangement consists of joined steel modular frames. Bolted steel-plate connectors are used at the module junctions shown in the technical details. These connections bring adjacent frames together to form the wider accommodation floors and support alignment between the repeated room bays, corridor zone and dedicated sanitary areas.
This joined-module approach is important to the architectural configuration. Individual frames establish the repeatable building blocks, but the completed floor layout depends on those frames being coordinated as one building. Openings, partitions, internal walls, corridor lines and service positions must all relate to the same modular grid.
The system can be considered in the wider context of our flat-pack container house approach, where factory-prepared components and repeatable steel frames can be configured into larger project-specific buildings. In this case, the drawings move beyond a single module and document how multiple frames, room components and circulation spaces fit together across three levels.

External Stairs and Vertical Access
The project drawing package includes external stair components and their installation details. Positioning the stairs externally preserves the repeated internal room-and-corridor arrangement instead of inserting a stair enclosure into the accommodation bays shown on the floor plans.
This keeps vertical movement associated with the outside edge of the building while the central corridor remains the principal horizontal circulation route on each level. The stair drawings also give the project team a defined basis for reviewing how flights, landings and supporting components relate to the modular structure.
The access arrangement needs to be understood as a coordinated part of the building rather than as an accessory added after the room layout is fixed. Module positions, corridor endpoints, exterior elevations and stair interfaces all need to correspond. Including both plan information and stair installation details helps connect these elements within the same technical package.

Four-Slope Pitched Roof and Drainage Detailing
A four-slope pitched roof completes the upper part of the building. The drawing package includes roof installation and drainage details, showing how the roof form relates to the modular accommodation block beneath it.
For this three-storey configuration, the pitched roof creates one continuous roof form above the joined modules rather than leaving each room bay visually expressed as an independent roof unit. Its four slopes establish planned directions for runoff, while the accompanying drainage details identify the roof-and-drainage interfaces that must be coordinated during project development.
The drawings also include sandwich-panel and internal-wall details. These details explain how the enclosure and internal divisions are assembled around the steel modular frames. No specific fire, thermal, acoustic or other performance values are assigned in this case study; those requirements would need to be defined for the intended project specification.

Electrical and Sanitary Coordination
The technical package contains lighting and socket layouts alongside sanitary-installation information. Their inclusion allows the accommodation plans to be reviewed not only as room diagrams but also as serviced spaces.
Lighting points follow the room, corridor and washroom organization shown on the relevant floors, while socket layouts identify the planned electrical positions within the accommodation arrangement. These drawings create a reference for coordinating service locations with internal walls, doors and repeated module boundaries.
The sanitary drawings cover both types of washroom configuration used in the building: private en-suite facilities on the first floor and shared or public washroom zones on the upper floors. This distinction matters because the plumbing arrangement associated with an individual room differs from the concentrated service requirements of a shared sanitary area.
By addressing the two sanitary strategies separately, the drawing package supports more precise review of room layouts and service interfaces. The available information does not define final site utility connections, which would remain part of project-specific coordination, but it establishes the internal installation arrangement represented in the building plans.

A Multi-Discipline Drawing Package
The public technical package includes floor plans, elevations, module parts, stair components, roof details, electrical layouts and sanitary-installation drawings. Together, these disciplines describe the building from several connected viewpoints.
The floor plans establish the 40-room arrangement, central corridors and washroom zones. Elevations show the external composition of the three-storey block. Module-part drawings explain the repeated building components and frame relationships, while the stair and roof sheets address major external assemblies. Electrical and sanitary sheets add the service information required to interpret the rooms as functional accommodation spaces.
This level of documentation is valuable during a buyerโs configuration review because it exposes the interfaces that need agreement before a project moves into detailed development. Room quantities alone cannot explain how a multi-storey modular building works. The buyer also needs to see how modules connect, how circulation is arranged, where sanitary functions are concentrated and how external assemblies relate to the main structure.
Readers assessing other three-storey layouts may also compare the planning approach with our Japan three-storey modular dormitory case. For a different accommodation format and deployment context, the rapid-deploy workforce accommodation case offers another reference point.
What Buyers Can Take from This Configuration
This project provides a concrete reference for buyers who need to discuss more than a generic request for a modular dormitory. It shows how a brief can be translated into a defined room count, typical room dimensions, corridor width, sanitary strategy, structural joining method, external access arrangement and roof form.
The mixed floor layouts are particularly useful during early configuration discussions. A buyer can consider whether every room should be en-suite, whether some floors should use shared washrooms, or whether different room categories should be distributed across the building. These decisions affect the architectural arrangement and the internal service layout, so they are better addressed before the room schedule and technical interfaces are finalized.
The public drawing package can be reviewed here: View the public CASE-006 technical drawing pack (PDF).
This three-storey modular accommodation building organizes 40 rooms around central corridors within an approximate 24,000 x 13,900 mm footprint. Its combination of first-floor en-suite rooms, upper-floor shared washrooms, joined steel modular frames, external stairs and a four-slope pitched roof demonstrates how repeated modules can be developed into a coordinated multi-level dormitory or staff-accommodation configuration.
KUBO systems relevant to this project
Flat Pack Container House
Repeatable steel modules coordinated into a larger project-specific accommodation building.
Detachable Dormitory Block
Multi-room accommodation units organized around corridors, washrooms and external access.
Workforce Accommodation Solutions
Project-specific room, circulation, sanitary and service coordination for workforce housing.
KUBO Prefab Editorial Team
About the Author
Prepares project case content for B2B buyers comparing modular accommodation layouts, circulation, utilities and building-system options.
KUBO Project Engineering Team
Technical Review
Reviewed against the public CASE-006 drawing package. Review does not replace local approvals, permits or project-specific engineering calculations.
Editorial Note
Planning Reference
The project location is confidential. Only the documented building configuration and drawing disciplines are presented.
Discuss a project-specific multi-storey accommodation layout
Share the room count, room standard, washroom strategy, shared facilities, site conditions, utility requirements and target schedule.
Three-Storey Modular Accommodation โ Questions Buyers Ask
How many rooms are shown in the CASE-006 building?
The three floor plans show 40 rooms across one three-storey modular accommodation building. Bed count and final occupancy are not stated.
What are the typical module and corridor dimensions?
The typical room module is shown as 3,000 x 5,950 mm, and the central corridor is shown as 2,000 mm wide.
How are the washrooms arranged?
The first floor shows 16 en-suite rooms. The upper floors use shared washroom zones positioned within the repeated room-and-corridor layout.
Why does the design use a central corridor?
The corridor organizes rooms on both sides around one repeated circulation line and coordinates the room bays, shared sanitary zones and access points within the modular grid.
How are the modules structurally connected?
The drawing package shows joined steel modular frames using bolted steel-plate connectors. Project-specific structural calculations and load requirements are not stated in this public case.
What access and roof systems are included?
The package includes external stair components and installation details, together with a continuous four-slope pitched roof and roof-drainage details.
What electrical and sanitary information is available?
The public package includes lighting and socket layouts plus sanitary-installation details for the en-suite rooms and shared washroom zones. Final site utility connections are project-specific.
What information should a buyer provide for a similar project?
Share the required room count, room standard, washroom strategy, shared facilities, site conditions, utility requirements, destination and target schedule for project-specific review.